We are offering wide range of Biohazard Cabinet to our clients. Biosafety cabinet Class I/II(A2,B2)/III/PCR cabinets ( We can supply Sizes of 700, 1100, 1300, 1500 & 1800 mm)
Probably we are the only bio-safety cabinet supplier in the world with a remote control operation including front sash movement, fan speed control with total microprocssor controlled operation of the instrument for the safety of the User, Product and Environment Technical features of our cabinets:
- Seamless stainless steel body of cabinet
- 10oC sliding front sash with patent No: 200430047816.7
- UV lamp
- VFD display with patent No: 200420053408.7
- Reserving time function with patent
- Socket
- Foot switch
- Collecting tank
- Frame
- The filter replacement and blower maintenance can be finished in front of the cabinet
- Draining system
- UV lamp timer
- Air inflow
Technical Data of our 1500 mm width cabinet:
Model
|
BSC-1500IIB2-X
|
External size(mm)
|
1500x850x220
|
Main filter
|
HEPA filter/ULPA(one piece)
|
Filteration performance
|
99.999%
|
Ehaust filter
|
HEPA filter/ULPA (one piece)
|
Fileration performance
|
99.999%
|
Inflow velocity
|
0.65+-0.015m/s
|
Downflow velocity
|
0.37+-0.015m/s
|
Air circulation
|
0
|
Exhaust air
|
100%
|
Lighting
|
680Lux
|
Vibration
|
The net displace is no more than 5 õm(rms) when the frequency is from 10Hz to 10kHz
|
Noise
|
65dB
|
Clean level
|
Class 10
|
Control system
|
Microprocessor
|
Front panel
|
Multi-layer doubling toughened glass
|
Material
|
Type 304 stainless steel for working zone interior
|
Voltage
|
220/50Hz+-10%
|
Power
|
4000ml, fitted with draining valve
|
Stability
|
The core part can stand 23kg pressure without permanent distortion
|
Biosafety
|
- Personnel safety: Hammerblow samples 10CFU/time Silt sampless 5CFU/time
- Product safety: The microganism germ falls 5CFU/time
- Cross infection safety: The microorganism germ falls 2CFU/time
|
We are the suppliers of Class-I, Class-II A2 (70% recirulcated air and 30% filtered and vented out), B2 (100% vented out), Class-III microbiological safety cabinets, PCR cabinets manufactured as per NSF 49 guidelines and with ISO and CE certifications. Our cabinets are individually tested with remote control opration and foot switch. VFD Patented display. Class 1 Biological Safety Cabinet
The Class 1 Biological Safety Cabinet provides personnel and environmental protection, but no product protection. It is similar in air movement of a chemical fume but usually has a limited fixed work access opening and the exhaust air must be HEPA filtered, to protect the environment. The Class I Biological Safety Cabinet is designed for general microbial research with low-and moderate-risk agents. In addition, the work zone, which type is much smaller than a chemical fume hood, is geared to working with biological whose process / producers dictates the use of moderate amounts of volatile liquids, that are suitable for re-circulating cabinets.
Class II Biological Safety Cabinet
As indicated in the previous section selecting a Class II Biological Safety Cabinet must take into consideration a considerable number of factors which include, among others, the work being done within the cabinet, the facility requirement based on bio safety levels, the location of the cabinet within the laboratory itself, the installation requirements of the cabinet, and the exhaust/supply systems (s) to both the laboratory and the cabinet, whether or not the cabinet is to be vented.
Class III Biological Safety Cabinet
The Class II biological safety cabinet was designed for work with bio safety level 4 microbiological agents and provides maximum protection to the environment and that worker. It is a gas-light enclosure with a non-opening, completely sealed, viewing window. Access to the interior of the cabinet is through a double-door pass-through "Interchange" box (such as an autoclave) that can be decontaminated between uses and/or a dunk tank that is accessible through the cabinet floor into the floor of a Class I or Class II Cabinet. Reversing that process allows for safe removal of materials from the Class II bio safety cabinet.
|